CAT: BFP/VCAR
CRP04HP
1
2
1
2
CRP 04 HP NA ..
CRP 04 HP NC ..
IE/CRP04HP/002/2012 SHEET: 1/2
8
10
3 Corsa
(Stroke)
P3
38.2 max
2
1
3/4-16 UNF
20
12.7
61.8
2.5
88.8
278.838.5
47.8
23.5
36
19
24
8
4 corsa
(stroke)
36
47.8
23.5
2
1
85.2
27
12.7
38.5
11.8
3/4-16 UNF
3
20
8
93.2
24
HIGH PRESSURE PILOTED OPERATED SOLENOID VALVE
FEATURES
HYDRAULIC SYMBOLS
Max. pressure 370 bar
Max. Flow 30 l/min
Max. Leakage (0 ÷ 10 drops/min) 0 ÷ 0.5 cm
3
/min
Max. excitation frequency 2 Hz
Duty cycle 100% ED
Hydraulic fluids DIN 51524 Mineral oils
Fluid viscosity 10 ÷ 500 mm²/s
Fluid temperature -25°C ÷ 75°C
Ambient temperature -25°C ÷ 60°C
Max. contamin. level class with filter ISO 4406:1999 - class 19/17/14
Cartridge filter 280µm
Type of protection
(in relation to the connection used)
IP65
Weight (with coil) 0.35 kg
Cartridge tightening torque 25 ÷ 30 Nm
Coil ring nut tightening torque 7 Nm
Cavity (3/4 - 16 UNF)
CD018006
(See section 15)
Normally open Normally closed
Emergency P3
SOLENOID VALVES - 2-WAY
Connector to be ordered separately, see sect. 18
The pilot-operated electric 2-way 2-position directional valve is controlled
electrically. For high pressures.
The tapered poppet is in tempered and ground steel.
Available in normally open (NA) or normally closed (NC) versions.
- NA, free passage from 2 to 1 with de-energised coil.
- NC, free passage from 2 to 1 with energised coil or from 1 to 2 with de-
energised coil.
The valves work with DC coils whereas RAC coils with a connector with incor-
porated rectifier must be used for AC applications.
The sleeve is in galvanised steel.
00012024
Spare seals kit
Page: 72
HOME INFO VALVES INDEX
CAT: BFP/VCAR
CRP 04 HP NC. CRP 04 HP NA.
CRP04HP
IE/CRP04HP/002/2012 SHEET: 2/2
CRP 04 HP ** A E * ** 1
8
12
21
Q (l/min)
P(bar)
0
2
4
6
8
10
12
14
0
5
10 15 20
25 30
21
Q (l/min)
P(bar)
0
2
4
6
8
10
0
510
15 20 25
30
CRP04HPNA
CRP04HPNC
Q (l/min)
P(bar)
0
50
100
150
200
250
300
350
400
0
510
15 20 25
30
ORDERING CODE
PRESSURE DROPS
Series
Size
Version
Version
Seat size
00 = No variants
P3 = Rotary emerg. (..NA)
SF =
Without cartridge filter
FK = With flying leads 600 mm (1)
AJ = AMP Junior connection (1)
1 2 Only with coil not energised
LIMITS OF USE
The tests were carried out with the solenoids at operating temperature, with a supply voltage 10% below nominal value and with a 40°C fluid temperature. The fluid used is
a mineral oil with viscosity of 46 mm²/s at 40°C.
Voltage
Variants
(1) Only voltages 12 VDC - 24 VDC
(2) With rectifier: 24 VAC/50-60Hz
(3) With rectifier: 115 VAC/50Hz - 120 VAC/60Hz
(4) With rectifier: 230 VAC/50Hz - 240 VAC/60Hz
(5) Performance are guaranteed only using valves completed with BFP coil
SOLENOID VALVES - 2-WAY
Connector to be ordered separately, see sect. 18
1 = Serial No.
04 = 3/4 - 16 UNF
NA = Normally open
NC = Normally closed
HP = High pressure
CRP = High pressure piloted operated
solenoid valve
A = Standard - Ø 12.7 mm
E = With emergency
Coils technical data, see sect. 17
DC 22W (C36)
L = 12 VDC
M = 24 VDC
N = 48 VDC
V = 28 V DC
4 = 14 VDC
2 = 21.6 VDC RAC (2)
Z = 102 VDC RAC (3)
X = 205 VDC RAC (4)
W = Without coil (5)